Back to catalog
300/500 V 70°C 60227 IEC 10Zoom
Low Voltage

Construction

1Conductor
Solid or circular stranded annealed copper
2Insulation
Polyvinyl chloride (PVC/C) / Blue, Brown
3Inner covering
Polyvinyl chloride (PVC), Black colour
4Outer sheath
Polyvinyl chloride (PVC/ST4), Black colour
60227 IEC 10

300/500 V 70°C 60227 IEC 10

Bangkok Cable

2 CORES - LIGHT POLYVINYL CHLORIDE SHEATHED CABLE

Voltage
300/500 V
Standards
TIS 11 Part 4-2553
features

Key Features

  • Flexible
  • Flame Retardant
applications

Applications

  • Suitable for general-purpose wiring.
  • For installation in raceways and shall be protected water into raceways.
  • Suitable for installation on cable trays or cable ladders.
  • Not permitted for installation in underground ducts or for direct burial in ground.
standards

Standards

  • TIS 11 Part 4-2553
specifications

Technical Data

Maximum conductor temperature
70°C
Rated voltage
300/500 V
AC test voltage
2,000 V
Markets
Industrial
specification table

Cable Size Table

13 sizes

No.of coreConductorThickness of insulationmmThickness of inner sheath coveringmm (Approx.)Thickness of outer sheathmmOverall diameterInsulation resistance at 70°CMΩ.km (Min.)Current ratingCurrent rating Laid on cable ladder at 40°C ambientACable weightkg/km (Approx.)Standard lengthm
Cross-sectional areaPhase mm² (Nominal)Cross-sectional areaGround mm² (Nominal)No. of wires(Min.)Diametermm (Approx.)Lower limitmmUpper limitmm
21.5-11.360.70.41.27.6100.01116120100/C
21.5-71.610.70.41.27.810.50.0116130100/C
22.5-11.740.80.41.28.611.50.0122160100/C
22.5-72.030.80.41.29120.00922170100/C
24-12.20.80.41.29.612.50.008530210100/C
24-72.570.80.41.210130.007730220100/C
26-12.70.80.41.210.513.50.00737260100/C
26-73.10.80.41.211140.006537290100/C
210-13.510.61.41316.50.00752430100/C
210-73.9810.61.413.517.50.006552470100/C
216-7510.61.415.5200.005270650500/D
225-76.331.20.81.418.5240.00588980500/D
235-77.591.211.62127.50.00441101310500/D